-Universal testarea mașinilor, Impact testarea mașinilor-

Blog

» Blog

tester de debit de topire

Aprilie 23, 2022

tester de debit de topire

Melt Flow Rate Test Equipment,MFI Melting Flow Index Tester,MFI Testing Device ISO1133

Melt Flow Rate Test Equipment,MFI Melting Flow Index Tester,MFI Testing Device ISO1133

Discription:

Melt flow rate testing instrument can be used for ABS, polistiren, polietilenă, polipropilenă, polyamide, rășină fibroasă, acrylate, POM, plastic fluor, polycarbonate and other plastic materials, the melt flow rate (MFR) or the melt volume flow rate (MVR) to be determined.

 

Standard:

GB/T3682-2018,ISO1133-2011, ASTM D1238

 

Melt Flow Rate Test Equipment,MFI Melting Flow Index Tester,MFI Testing Device ISO1133

Product Character:

 

1.English LCD Touched Screen.

2.Hand automatic cutting material.

3.Double temperature control system, temperature control precision is more accurate, higher heating efficienc

4.Double imported sensors, more accurate temperature gradient from top to bottom, can be used independently, and improve the service life.

5. Cylinder for imports hartz alloying nitriding treatment, opening mould for carbon tungsten steel material, material reality.

6.Insulation barrels of sus304 stainless steel material for the whole, long-term high temperature does not rust.

7.Automatic calculation results, and print.

 

Test Methods:MFR Methods

Modul de afișare:English color touch screen display

 

Melt Flow Rate Test Equipment,MFI Melting Flow Index Tester,MFI Testing Device ISO1133

Specificație

 

 

Model LR-A001-A
Barrel parameters Inner hole 9.550±0.005mm
Pistons parameters Piston head: 9.474±0.005mm
Outlet length 8.000±0,025 mm
Paramters Extrusion hole 1=2.095±0.005mm
Temperature parameter With intelligent temperature control instrument, with four pairs of significant temperature setting control, PID parameters can be automatically set, precision up to ± 0.1 degree centigrade
Interval de temperatură Room Temperature~450degree centigrade
fluctuație de temperatură ±0.2 ℃
Uniformitatea temperaturii ± 1 ℃
Rezoluția afișajului temperaturii 0.1℃
rezoluţie afișaj 0.1℃
Maximum comsuption < 600W
Rezoluția afișajului timpului 0.1s
Weight parameters are as follows:
Precizia greutății ± 0.5%
Configurare de bază

 

A 0.325kg
B 1.2kg
C 2.16kg
D 3.8kg
E 5kg
 
F 10kg
 
G 12.5kg
H 21.6kg
 
Position detection
Loop distance from up and down 30mm
Control precision ± 0.1mm
Test flow control
Times of cutting the material 0~10 times
Material cutting interval 0~999s(set reference Table 2)
Control flow reaches the set temperature without volatility
Barrel temperature time 15 mă.
Material be installed 1 mă.
Material sample temperature recovery time 4 mă.
When binder set

1mă

Output mode Micro-automatic print output
Cut material methods The hand automatic cut into one body
Testul de sarcină Eight sets of weights
Putere AC220V±10% 50/60HZ

Poate iti place, de asemenea,